Test Code WILMP Hereditary Wilms Tumor Panel, Varies
Ordering Guidance
Customization of this panel and single gene analysis for any gene present on this panel are available. For more information see CGPH / Custom Gene Panel, Hereditary, Next-Generation Sequencing, Varies.
Targeted testing for familial variants (also called site-specific or known mutations testing) is available for the genes on this panel. For more information see FMTT / Familial Variant, Targeted Testing, Varies. To obtain more information about this testing option, call 800-533-1710.
If the reason for testing indicates WAGR syndrome (Wilms tumor, aniridia, genitourinary abnormalities, range of developmental delays), order CMACB / Chromosomal Microarray, Congenital, Blood.
Shipping Instructions
Specimen preferred to arrive within 96 hours of collection.
Specimen Required
Patient Preparation: A previous bone marrow transplant from an allogenic donor will interfere with testing. Call 800-533-1710 for instructions for testing patients who have received a bone marrow transplant.
Specimen Type: Whole blood
Container/Tube:
Preferred: Lavender top (EDTA) or yellow top (ACD)
Acceptable: Any anticoagulant
Specimen Volume: 3 mL
Collection Instructions:
1. Invert several times to mix blood.
2. Send whole blood specimen in original tube. Do not aliquot.
Specimen Stability Information: Ambient (preferred) 4 days/Refrigerated
Forms
1. New York Clients-Informed consent is required. Document on the request form or electronic order that a copy is on file. The following documents are available:
-Informed Consent for Genetic Testing (T576)
-Informed Consent for Genetic Testing (Spanish) (T826)
2. Molecular Genetics: Inherited Cancer Syndromes Patient Information (T519)
3. If not ordering electronically, complete, print, and send a Oncology Test Request (T729) with the specimen.
Secondary ID
614577Useful For
Evaluating isolated and syndromic causes of Wilms tumor
Establishing a diagnosis to guide management for individuals with Wilms tumor
Identifying a familial variant allowing for predictive testing and appropriate screening of at-risk family members
Special Instructions
Method Name
Sequence Capture and Targeted Next-Generation Sequencing followed by Polymerase Chain Reaction (PCR) and Sanger Sequencing
Reporting Name
Hereditary Wilms Tumor PanelSpecimen Type
VariesSpecimen Minimum Volume
1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Varies |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reference Values
An interpretive report will be provided.
Day(s) Performed
Varies
Report Available
21 to 28 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
81351
81405
81479
81479 (if appropriate for government payers)
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
WILMP | Hereditary Wilms Tumor Panel | 101671-6 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
614887 | Test Description | 62364-5 |
614888 | Specimen | 31208-2 |
614889 | Source | 31208-2 |
614890 | Result Summary | 50397-9 |
614891 | Result | 82939-0 |
614892 | Interpretation | 69047-9 |
614893 | Resources | 99622-3 |
614894 | Additional Information | 48767-8 |
614895 | Method | 85069-3 |
614896 | Genes Analyzed | 48018-6 |
614897 | Disclaimer | 62364-5 |
614898 | Released By | 18771-6 |